Preconditioned Air Unit (PCA) AHU manufacturers in Bangalore INR   0 INR  0
-NaN%

Preconditioned Air Unit (PCA) AHU manufacturers in Bangalore

Preconditioned Air Unit (PCA) AHU manufacturers in Bangalore Contact Cnc Associates Bengaluru Ph. +91 9902070764 / 08064518474 / 08064518475 cncassociates@gmail.com Technical Specifications: 320/120 270/100 210/80 160/60 120/45 90/35 318 kW 120 Tn 4 150 kg 167 kW 266 kW 100 Tn 3 800 kg 140 kW 212 kW 80 Tn 3 450 kg 107 kW 160 kW 60 Tn 3 100 kg 80 kW 125 kW 46 Tn 2 550 kg 60 kW 93 kW 35 Tn 2 250 kg 44 kW Cooling Capacity (*) Compressor Capacity (**) Number Compressors / Stages Length Width Height Weight Maximum Air Flow Available Static Pressure Discharge Temperature Power Supply Total Consumption (*) Refrigerant Sound level at 4.6m. Cnc Associates PCA unit is specially designed for heating and cooling all types of aircrafts and for providing maintenance personnel fast and easy access to all components. Mounted door Condensation Fan for easy access maintenance operations PCA Hose Connection Secondary Electrical Cabinet Main Electrical Pannel AIR OUTLET FOR HEAT DISSIPATION AIR OUTLET FOR PRE CONDITIONED AIR OF THE AIRPLANE AIR INLET FOR DISSIPATION AIR INLET FOR PRE CONDITIONED AIR OF THE AIRPLANE AIR INLET FOR DISSIPATIION Axial & helicoidal Fan Heat Exchanger Grill Protector (optional) 4/4 1.62 m 2.17 m -2 ºC to +2 ºC 400 V/3/50 Hz (***) 6 300 Pa 8 500 Pa 10 000 Pa 4.30 mTechnical Specifications 320/120 270/100 210/80 160/60 120/45 90/35 318 kW 120 Tn 4 150 kg 167 kW 266 kW 100 Tn 3 800 kg 140 kW 212 kW 80 Tn 3 450 kg 107 kW 160 kW 60 Tn 3 100 kg 80 kW 125 kW 46 Tn 2 550 kg 60 kW 93 kW 35 Tn 2 250 kg 44 kW Cooling Capacity (*) Compressor Capacity (**) Number Compressors / Stages Length Width Height Weight Maximum Air Flow Available Static Pressure Discharge Temperature Power Supply Total Consumption (*) Refrigerant Sound level at 4.6m. CNC ASSOCIATES’s PCA unit is specially designed for heating and cooling all types of aircrafts and for providing maintenance personnel fast and easy ac PCA operation temperature with R-410A: -40ºC to +46ºC Optional heating resistors available for lower ambient air temperature(*) at design conditions per ARI/ASHRAE 35 °CDB / 26 °CWB with refrigerant R-410A. (**) Nominal tons 60 Hz. (***) other voltages/frequency possible. (****) other refrigerant (R-134a) is possible. (R-134a refrigerant operation range temperature is: -40 ºC to +55 ºC) Standards & Regulations CNC ASSOCIATES’s engineering solutions comply with the following Standards and Regulations, where applicable: The QR code links directly to this brochure 220217 - Specifications are subject to change without prior notice and are not contractual AHM 650 (IATA) - Potable Water Servicing AHM 902 (IATA) - Environmental impact on the use of GSE AHM 910 (IATA) - Basic requirements for aircraft GSE AHM 913 (IATA) - Basic safety requirements for aircraft GSE AHM 922 (IATA) - Basic requirements for PBB Aircraft Interface AHM 973 (IATA) - Functional specification for a towed aircraft ground heater AHM 974 (IATA) - Functional specification for aircraft air conditioning unit AHM 1002 (IATA) - Environmental impact on the use of GSE EN Standards NFP 415 - 2016 EN 12312-4 - Passenger Boarding Bridges EN 12312-12 - Potable Water Service EN 12312-17 - Air conditioning equipment EN 12312-20 - Electrical ground Power Units Electromagnetic Compatibility (EMC) – (89/23/CEE) UNE-EN 1915-1:2013 - Aircraft ground support equipment. General requirements. Basic safety requirements About CNC ASSOCIATES CNC ASSOCIATES provides engineering know-how and result-driven solutions for the world’s leading international airports. From advanced boarding bridges and terminal solutions that deliver a better experience for passengers, to innovative ground support equipment and airport global services to improve performance on the apron, CNC ASSOCIATES is focused on working closely with its partners to enhance Airport operations worldwide. Cnc Associates takes your airport to the next level

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Louver Dampers Single, multiple and opposed blade louver dampers INR   0 INR  0
-NaN%

Louver Dampers Single, multiple and opposed blade louver dampers

Louver Dampers Single, multiple and opposed blade louver dampers The louver type of damper consists of several blades mounted parallel across a duct, with centrally pivoted. The drive for a louver is simple, needing only 90° of motion. If a damper must open or close quickly, the louver type is the only practical choice. In case of emergency actuators, air and oil cylinders will be able to actuate louver dampers with little difficulty. Louver dampers are best applied to balance or control flow, based on application/ service, the damper can be single or multiple louver type. Opposed blade louver dampers are used for finer control of a large volume of air/gas. Louver dampers in a coal fired unit range are located all the way from the induced draft fan and the primary air system to the flue gas scrubber outlets. Opposed blades louver dampers are the most effective type of damper for controlling the flow of gases with the least disturbance to flow in ducts. Blade pairs are carefully fitted to ensure precise operation in opposing directions, and thus creating highly controllable passages for the gas. A non-binding, fully adjustable external linkage is used to operate the damper. The double louver damper is used to combine flow control with the capability of 100 % isolation. The damper is configured with two rows of blades in a frame. Perfect isolation is achieved by closing the blades and pressurizing the space between the two rows with ambient air at a pressure greater than the upstream pressure in the duct. The air barrier prevents leakage of flue gas into the isolated area and also ventilates the downstream area with clean air. Radial vane louver dampers have centre-supported radial blades spaced around a circular frame. They are rotated by a linkage outside the ring frame. The blades usually turn in the same direction, so this damper imparts whirl to the air. Contact Cnc Associates Bengaluru Ph. +91 9902070764 / 08064518474 / 08064518475 cncassociates@gmail.com

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Industrial Environment INR   0 INR  0
-NaN%

Industrial Environment

Product Description: In an Industrial Environment, proper ventilation should be provided to maintain the efficiency, health and safety of workers. The indoor environment of any industries may have sources generating heat, fumes, VOCs , dusts etc..that are harmful to workers and it should be controlled and kept within allowable limits set by OSHA (Occupational Safety & Health Administration) and Industrial Hygienists standards to minimize absenteeism of workers, Increase productivity, avoid explosion and fire at workplace Based on the indoor air contaminants concentration, allowable TLV-STEL ( Threshold limit value - Short Term Exposure Limit) Values, Explosion limits, any of below ventilation methods can be chosen to effectively maintain industrial environment. Industrial Ventilation Types: Local Exhaust Ventilation ( For removing pollutants from source for highly harmful gases) Dilution Ventilation system ( Diluting the concentration to allowable safe limit, for medium to low harm gases) Makeup air or Replacement type (for heat and oxygen supply HVAC Ventilation (Primary for Human comfort Recirculation system. CNC had a strong team of engineers having deep knowledge in Designing, Errection and commissioning of Industrial ventilation products, AHU, Industrial Ducting, Air cleaning equipments, Blowers and chimney provides complete Industrial Ventilation and air pollution control solutions to its customers across various industries

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Manufacturer Flexible duct, Semi rigid flexible duct, Kitchen chimney pipe Uninsulated flexible duct INR   0 INR  0
-NaN%

Manufacturer Flexible duct, Semi rigid flexible duct, Kitchen chimney pipe Uninsulated flexible duct

Manufacturer Flexible duct, Semi rigid flexible duct, Kitchen chimney pipe Uninsulated flexible duct The corrugated aluminum is twisted to form a continuous airtight lock-seam AS-type air duct is suitable for heating, ventilation and air conditioning systems. Technical Data Construction Materials The air duct is made entirely of aluminum that is twisted to form a continuous airtight lock-seam. Operating Pressure (inches water column) Positive = 6 inches H²O (1.5 kPa) Negative = 6 inches H²O (1.5 kPa) Operating Temperature Range Minimum = -20°F (-28°C) Maximum = 435°F (224°C) Velocity (feet per minute) 5, 000 f.p.m. (25 m/sec) Surface Burning Characteristics Maximum Flame Spread = 0 Maximum Smoke Development = 0 Available Diameters 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 inches Available Lengths 10 feet OUR GUARANTEE are COMPETITIVE PRICING QUALITY WORKMANSHIP CUSTOMER SERVICE RELIABLE PRODUCTS Contact Cnc Associates Bengaluru Ph. +91 9902070764 / 08064518474 / 08064518475 cncassociates@gmail.com

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Modular Extraction Hoods/Welding fume extractor/Fume exhaust INR   0 INR  0
-NaN%

Modular Extraction Hoods/Welding fume extractor/Fume exhaust

Modular Extraction Hoods/Welding fume extractor/Fume exhaust Welding fume control and filtration in a flexible and portable way. Cnc new Modular Extraction Hood is engineered to contain and extract welding, cutting, arc gouging, and grinding fume from the work environment. Its innovative design brings a reliable and practical solution to the market. These units are ideal for robotic, hard automation and manual applications. OUR GUARANTEE COMPETITIVE PRICING QUALITY WORKMANSHIP CUSTOMER SERVICE RELIABLE PRODUCTS Contact Cnc Associates Bengaluru Ph. +91 9902070764 / 08064518474 / 08064518475 cncassociates@gmail.com

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Fumehood - Laboratory & Chemical Fume Hoods Fumehoods are a kind of Local Exhaust Ventilation type INR   0 INR  0
-NaN%

Fumehood - Laboratory & Chemical Fume Hoods Fumehoods are a kind of Local Exhaust Ventilation type

Fumehood - Laboratory & Chemical Fume Hoods Fumehoods are a kind of Local Exhaust Ventilation type, and are used specifically to contain harmful fumes that are generated while doing chemical experiments in research laboratory, Pharma labs etc.. CNC designs, manufactures, tests and supplies widest range of fumehoods including Table top fumehoods, Standard floor standing fumehoods, Perchloric Fumehoods, Acid digestion Fumehoods, Radioactive fumehoods and Walk-in type fumehoods. All our fumehoods are ergonomically designed, Robust build with complete customization options to customers boosting maximum productivity and safety. Choose any of our Fumehood types below or call us @ +91-9902070764 or send us enquiry cncassociates@gmail.com. We are very much happy to assist you in selecting and customizing our widest range of fumehods that best suits your needs and fits in your Lab

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Spiral ducts and Vinyl-Coated Pipe INR   0 INR  0
-NaN%

Spiral ducts and Vinyl-Coated Pipe

Spiral ducts and Vinyl-Coated Pipe Spiral duct, Bangalore - Cnc Associates. The chemical inertness of PVC combined with the strength of spiral pipe make vinyl coated duct ideal for chemical fume removal applications and for underground HVAC applications where strength and resistance to corrosive salts and other minerals found in backfill are prerequisites. Our Cnc Associates vinyl-coated spiral pipe is manufactured from galvanized steel coated with a polyvinyl chloride material with an outside and inside thickness as per customer. This is very usefull for special purposes. External corrugations are standard for 14″ diameter for underground applications. Standard gauges are: 22 & 24 gauge. Spiral Insulated Pipe Cnc Associates dual-wall spiral insulated duct adds both thermal insulating and sound attenuating benefits to any air distribution system.Cnc dual-wall product consists of inner and outer spiral pipes with a layer of glass fiber insulation sandwiched in between, thus reducing noise and conserving energy. Material Handling and Truck Loading The ability of spiral pipe to handle high pressures, its efficient airflow characteristics, and its low pressure loss make Spiral pipe ideal for bulk material handling applications.Cnc offers a complete line of trailer loading accessories, including ball joints, diverter valves, quick disconnects, and air actuated gates. Fittings Spiral Manufacturing offers a complete line of seam welded, slip-joint fittings designed especially for use with Cnc Spiral pipe. Standard fittings include many types of elbows, crosses, tees, laterals, reducers, and other components fabricated from standard thicknesses. Contact Cnc Associates Bengaluru Ph. +91 9902070764 / 08064518474 / 08064518475 cncassociates@gmail.com

INR 0 INR 0

Availability:True

Pay mode:COD only

view details
Wind Turbine Ventilators INR   0 INR  0
-NaN%

Wind Turbine Ventilators

Product Description: Wind Turbine Ventilators Enriched with rich industrial experience, we offer technologically advanced range of Wind Turbine Ventilators. These Wind Turbine Ventilators ensure proper ventilation and can be easily substituted. Being dimensionally accurate, functionally efficient and having long service life, these Wind Turbine Ventilators are extensively used in different commercial and industrial sectors. To maintain the quality of these ventilators, these are fabricated using quality tested components and advanced technologies. Features: Runs on wind energyTrouble free performanceSuperior quality Cnc Associates Bengaluru Ph. +91 9902070764 / 08064518474 / 08064518475 cncassociates@gmail.com